May be performed independently. This card describes only the chamber construction and correct placement of the nebuliser’s supplied nebuliser cup. Solutions and nebulisation settings are selected under Card 41.
Main principle: in our design, aerosol enters from BELOW. The supplied nebuliser cup remains outside, beneath the container floor, in its vertical operating position; only its upper outlet section passes through the hole in the floor. We do not introduce the nebuliser cup through the side. You will need: a transparent plastic container of approximately 15–25 L; two stable supports or a stand to raise the container above the surface; a compressor nebuliser; its supplied nebuliser cup; its supplied tubing of sufficient length; a tool for making holes.
1. Choose a transparent container in which the hedgehog can lie in a natural position, turn around and change position if necessary. The lid must prevent escape, but the chamber must not become airtight.
2. Place the container on stable supports so that there is free space underneath its base. The clearance must be sufficient for the supplied nebuliser cup to stand vertically beneath the base without pressing against the table or kinking the tubing.
3. In the container floor, near one wall, make a hole for the upper outlet section of the nebuliser cup. The cup itself remains OUTSIDE, beneath the container. Do not lay it on its side or insert it fully into the chamber.
4. Fit the nebuliser cup from below in its normal vertical position so that its outlet passes through the hole in the floor and aerosol enters upwards from below. The hole must not be noticeably larger than the outlet: a large open gap around it is unnecessary.
5. Position the compressor as far from the container as the supplied tubing allows. Use long manufacturer-supplied tubing without kinks or tension; place the compressor on a stable surface, with soft padding if necessary to reduce vibration. Do not obstruct its ventilation openings.
6. In the upper part of the opposite wall of the container, make 6–10 ventilation holes approximately 8–10 mm in diameter. This creates a directed aerosol path: from below near one wall → through the chamber volume → out through the upper holes on the opposite side.
7. Do not cover the entire floor with soft or absorbent material: it will absorb some of the aerosol and quickly become wet. Leave the area around the lower aerosol inlet clear. To reduce stress, a small non-absorbent shelter or a limited non-absorbent resting surface away from the aerosol inlet is acceptable, provided it does not obstruct the flow or prevent observation of the hedgehog.
8. Before first use, run the system WITHOUT the hedgehog for 1–2 minutes. Check that the nebuliser cup operates vertically, aerosol enters the container from below and spreads throughout the chamber, and air and aerosol escape freely through the upper holes. Check that nothing vibrates, tips over or blocks the outlets.
9. After checking, switch off the device, place the hedgehog inside and perform the procedure under Card 41.
DO NOT: insert the nebuliser cup from the side; lay it horizontally; rest the container directly on the nebuliser cup without stable supports; block the upper ventilation holes; direct the aerosol jet straight at the face; cover the entire floor with an absorbent pad.
Notes
Why the inlet is underneath. In this design, the supplied nebuliser cup must remain in its vertical operating position. A technically stable, reproducible arrangement is therefore to leave it beneath the container and introduce aerosol through a hole in the floor. Why the container is raised. The clearance beneath the base is not for chamber ventilation, but to accommodate the nebuliser cup and tubing without tilting, pressure or kinking. Why there is no continuous absorbent bedding. Absorbent material quickly takes up some of the aerosol and becomes damp; in this card, free aerosol distribution and visual monitoring of the animal take priority. Next steps: procedure settings and monitoring the hedgehog → Card 41.